Burner motor type eb 95 c 28/2 90 w- DIFF pour Bentone - 11593101
  • Burner motor type eb 95 c 28/2 90 w- DIFF pour Bentone - 11593101
  • Burner motor type eb 95 c 28/2 90 w- DIFF pour Bentone - 11593101

Burner motor type eb 95 c 28/2 90 w- DIFF pour Bentone - 11593101

432130
€266.42

For burners HS10-HS10R-HS20

Quantity

Colissimo Delivery expected from 2026-09-24

Available

Delivery & returns
  • ✓ Free delivery on orders over €79 in France
  • ✓ Free returns within 30 days
Find out more about terms and conditions

For burners HS10-HS10R-HS20

Features of product: BURNER MOTOR TYPE EB 95 C 28/2 90 W- DIFF POUR BENTONE - 11593101

Package Weight (kg)
2.633
Package Height (m)
0.16
Package Width (m)
0.175
Package Length (m)
0.285
Ø
8
Capacity (l)
3
Current
0.7
Number
1
Power (W)
90
Rotation
G

Repairing a Bentone Burner: Clean Combustion and Safe Operation

Bentone burners are valued for their reliability, but like any combustion system, they depend on precise adjustments and well-maintained components. A worn electrode, a miscalibrated nozzle, or a flame detection fault can lead to difficult starts, incomplete combustion (soot), or safety shutdowns. Replacing the correct part restores stable flame and consistent performance.

DIFF® Bentone spare parts cover critical burner elements: nozzles, ignition electrodes, detection cells, and safety boxes. These components directly impact the startup sequence and flame monitoring. Precise functional compatibility is essential for maintaining operational safety and combustion stability.

Essential Components for Your Repair

The most common failures often involve:

  • Nozzles: calibration of flow rate and spray angle. An unsuitable nozzle compromises combustion and promotes fouling.

  • Electrodes / Ignition: if the burner starts poorly or goes into safety mode at startup, the ignition needs to be checked.

  • Detection / Safety Box: checks the presence of a flame and provides protection in case of anomalies.

How to Identify the Right Bentone Part?

A visually similar part may differ in technical characteristics (calibration, connectivity, type of cell, box reference). Identify the burner’s reference and verify the reference of the original component.

Technical Advice: after replacement, an air/fuel adjustment check is recommended to stabilize the flame and limit fouling.