Electrode unit ELO1B40H/56H- DIFF pour Elco - 13007690
  • Electrode unit ELO1B40H/56H- DIFF pour Elco - 13007690
  • Electrode unit ELO1B40H/56H- DIFF pour Elco - 13007690

Electrode unit ELO1B40H/56H- DIFF pour Elco - 13007690

402400
€28.43

Electrode unit ELO1B40H/56H

Quantity

Colissimo Delivery expected from 2026-09-24

Available

Delivery & returns
  • ✓ Free delivery on orders over €79 in France
  • ✓ Free returns within 30 days
Find out more about terms and conditions

Electrode unit ELO1B40H/56HAdditional information:This part is an original spare part FROM parts manufacturer, it is labelled AND packaged under the DIFF distribution brand.

Additional information:
This part is an original spare part from parts manufacturer, it is labelled and packaged under the DIFF distribution brand

Features of product: ELECTRODE UNIT ELO1B40H/56H- DIFF POUR ELCO - 13007690

Package Weight (kg)
0.029
Package Height (m)
0.015
Package Width (m)
0.04
Package Length (m)
0.1
C
18.0
Ø
6.35mm
A (mm)
25.0
B
46.0
Number
1
Product type
Electrode

Repairing an Elco Oil Burner: Reducing Fouling and Stabilizing the Flame

Elco oil burners are designed to operate reliably, but the combustion quality heavily depends on the condition of the components and adherence to adjustment parameters. A fouled nozzle, unstable pump pressure, or ignition failure can result in incomplete combustion, generate soot, and lead to safety shutdowns. Targeted maintenance often allows for a stable operation without replacing the entire burner.

The Elco DIFF® spare parts cover the essential components for the combustion cycle: calibrated nozzles, ignition electrodes, high-voltage transformers, detection cells, and safety boxes. These elements are crucial for ignition, flame stability, and combustion monitoring. Functional compatibility is critical, especially regarding flame detection and boxes, to avoid recurring safety shutdowns.

Essential Components for Your Troubleshooting

Common malfunctions are often related to:

  • Nozzles: flow rate and spray angle. A non-compliant nozzle degrades combustion and promotes fouling.

  • Ignition: electrodes and transformers. In case of starting failures, ignition is a priority control point.

  • Detection / Safety: cell and control box, essential for validating the flame and securing the sequence.

How to Identify the Right Elco Part?

Two similar parts may differ in key characteristics (connectors, calibration, box reference). Locate the burner reference and compare it to the original component reference before ordering.

Technical Advice: after replacing a nozzle or an ignition component, a combustion check (air/oil) helps stabilize the flame and limit deposits.